Nhà phân phối Load cell RTB series Schenck Process tại Việt Nam
Technical Data
Rated capacity |
Emax |
0,13 t |
0,25 t |
0,5 t |
|
||
Accurate class |
|
C3 |
C3 |
C3 |
C3MI7.5 |
C6 |
Bezug |
Sensitivity |
Cn |
1 mV/V ±0.1 mV/V |
1.75 mV/V ±0.1 mV/V |
2 mV/V ±0.1 mV/V |
|
||
Combined error |
Fcomb |
±0.018 % |
±0.023 % |
±0.0115 % |
Cn |
||
Minimum dead load output return |
Fdr |
±0.0167 % |
±0.0167 % |
±0.0066 % |
±0.0083 % |
Cn |
|
Creep (30 m) |
Fcr |
±0.012 % |
±0.0245 % |
±0.0123 % |
Cn, Btn |
||
Hysteresis |
|
±0.017 % |
±0.0167 % |
±0.0083 % |
Cn, Btn |
||
Temperature effect on zero sensitivity per 10K |
TK0 |
±0.008 % --- |
±0.014 % ±0.007 % |
±0.014 % --- |
±0.009 % ±0.005 % |
Cn, Btn Option MR |
|
Temperature effect on sensitivity per 10K |
TKc |
±0.008 % |
±0.01 % |
±0.005 % |
Cn, Btn |
||
Maximum number of load cell intervals For multi-divisional scales: |
nLC Z |
3000 |
3000 |
6000 |
|
||
|
7500 |
|
|||||
Minimum load cell verification interval |
Vmin |
Emax/17500 ----- |
Emax/10000 Emax/20000 |
Emax/10000 --- |
Emax/15000 Emax/28000 |
Standard Option MR |
|
Min. utilisation range |
Bamin |
17 % --- |
30 % 15 % |
30 % -- |
40 % 21 % |
Emax Option MR |
|
Max. utilisation range |
Bamax |
100 % |
Emax |
||||
Load limit * |
Ll |
150 % |
Emax |
||||
Max. transverse load |
Lq |
100 % |
Emax |
||||
Input resistance |
Re |
1260 W ±100 W |
1100 W ±50 W |
1110 W ±50 W |
|
||
Output resistance |
Ra |
1020 W ±0.5 W |
1025 W ±50 W |
1025 W ±25 W |
|
||
Zero signal |
S0 |
1 % |
1.5 % |
1 % |
Cn |
||
Supply voltage |
Us |
max. 30 V (recommended): 5 V … 15 V |
|
||||
Nominal temperature range |
Btn |
-10 °C … +40 °C |
|
||||
Service temperature range |
Btu |
-30 °C … +85 °C |
-30 °C … +75 °C |
|
|||
Storage temperature range |
|
-50 °C … +95 °C |
-50 °C … +80 °C |
|
|||
Protection class |
|
IP66 / IP68 |
|
||||
Cable specification |
|
length of cable 5 m, Screen insulated from housing (0.13 t), or connected to housing (0.25 t – 0.50 t) |
|
||||
Colour code |
|
Input + 82: pink / input - 81: grey output + 28: brown / output - 27: white |
|
||||
Material |
|
Stainless steel |
|
||||
Corrosion protection |
|
see table of Chemical resistance DDP8 483 |
|
||||
Recommended torque for attachment bolts |
|
8 Nm |
12 – 14 Nm |
|
|||
ATEX-approval |
|
II 2G; EEx ib IIC T6 / II 2D T70 °C |
|
Order No.
Variants |
Accuracy class |
||
|
C3 |
C3MI7,5 |
C6 |
0.13 t |
V041085.B01 |
--- |
--- |
0.25 t |
V041086.B01 |
--- |
--- |
0.50 t |
V041087.B01 |
V041087.B03 |
V041087.B06 |
0.25 t MR |
V041086.B07 |
--- |
--- |
0.50 t MR |
V041087.B07 |
--- |
please enquire |
Order No. Version ATEX II 2G; EEx ib IIC T6 / II 2D T70 °C |
|||
0.13 t |
V041085.B11 |
--- |
--- |
0.25 t |
V041086.B11 |
--- |
--- |
0.50 t |
V041087.B11 |
--- |
please enquire |
Đại lý phân phối Load cell RTB series Schenck Process tại Việt Nam
Load cell RTB series Schenck Process Vietnam
- Ashcroft
- AT2E
- MARK 10
- BIHL WIEDEMANN
- SPOHN BURKHARDT
- Schenck Process
- Baumuller
- CS Instruments
- COMET SYSTEM
- KELLER-ITS
- Guenther
- GEMU
- KOGANEI
- MATSUSHIMA
- NIRECO
- OHKURA
- Redlion
- SHINHO SYSTEM
- TDK LAMBDA
- Teclock
- SITEC
- TERACOM
- Tektrol
- Medenus
- EPI Flowmeter
- Okazaki
- Ulticell
- Netter Vibration
- MINIMAX
- KRACHT
- HELUKABEL
- THIẾT BỊ KHÁC
-